Page view 22
SW USB Series • SIS Conguration and Control
SIS Configuration and Control, cont’d
4-4
SW USB Series • SIS Conguration and Control
4-5
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Firmware version, part number, and information requests
Request information I
Chn
X!
• InACT
X$
• OutACT
X$
• Emul
X%
X^
]
Show the selected input and output.
X$
= Activity of all inputs and outputs
For SW USB Plus only:
X%
= Mouse emulation switch position
X^
= Keyboard emulation switch position
For
X%
and
X^
: 0 = off (down); 1 = on (up).
Request part number N
60-95n-nn
]
Show the SW USB part number.
SW2 = 60-952-01, SW4 = 60-953-01,
SW4 USB Plus = 60-954-01.
Query rmware version Q
n.nn
]
Show rmware version, expressed to the second
decimal place.
Example:
Q
1.01
]
Query version and build *Q
n.nn.nnnn
]
Show rmware version and build number.
Reset
Reset
E
ZXXX
}
Zpx
]
Reset the switcher to factory default values.
Upload firmware
Upload rmware
E
Upload
}
...go
Upl
]
Upl appears after the upload is complete.
Command/response table for SIS commands
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Input selection
Select input
X!
! Chn
X!
]
Select input
X!
for both the SW USB and the
attached A/V switcher (if any).
Select SW USB input only
X!
^ USB
X!
]
Select input
X!
on the SW USB only (not passed
through).
Configure RS-232 pass-through
Send input selection commands
via contact closure, front panel,
or the RS-232 interface
E
0LOOP
}
Loop0
]
Input selection commands (only) issued via the
front panel, contact closure, or the RS-232 interface
are sent to an attached A/V switcher via the RS-232
Pass Thru port.
Send SIS commands via
computer RS-232 interface
E
1LOOP
}
Loop1
]
All available commands issued from an RS-232
interface can be performed by the SW USB and
passed through to a connected A/V switcher.
View loop out setting
E
Loop
}
Loop
X#
]
View pass-through setting
X#
. For
X#
:
0 = Input selection commands can be issued
through contact closure, the front panel, or
RS-232. (Loop 0 mode)
1 = All supported SIS commands can be issued
through the RS-232 interface. (Loop 1 mode)
Front panel lockout
Enable executive mode 1X
X#
]
Lock the front panel.
Disable executive mode 0X
X#
]
Unlock the front panel.
Lockout status X
X#
]
Show executive mode on/off status.