Extron electronic Extron Electronics Stereo Receiver RGB 203 RXI User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
RGB 203 Rxi • Setup Guide (Continued)
Conguring EDID (EDID Minder Model Only)
The Extron EDID Minder ensures the resolution of the video source signals are compatible with the display devices. The
RGB 203 Rxi provides 14 factory-installed EDID values that can be used. By default, the EDID value is set to a resolution of
1024x768, which will allow most source devices to boot up and provide a signal that can be displayed. Alternatively, you can
record your own EDID information and use those values, or use EDID information from a monitor connected to the Local
Monitor output.
User-Recorded EDID
You may also record EDID information from a specific monitor as follows:
1. Connect a display to the Local Monitor output (
c
) and power on the monitor and interface.
2. Turn the EDID Select dial (
o
) to setting 0.
3. Press and release the recessed Record button (
m
). The LED light will flash red slowly three times while the EDID is
recorded and return to green when recording is complete.
NOTE: This EDID will be stored in memory until deleted or overwritten.
Using Recorded EDID Values
NOTE: To boot up correctly, the source device must be able to receive EDID information during the boot process.
Therefore, the interface (and the local monitor, if using pass-through EDID) must be switched on before the
source is switched on.
Use factory-installed EDID information or the user-recorded EDID as follows:
1. If you have not already done so, connect the RGB 203 Rxi to the source device. Do not switch on the source device at
this time.
2. Set the left front panel DIP switch (
n
) to the required frequency (50 or 60 Hz).
3. Set the rotary switch to the required value (see the table below). Settings 1 - E are factory installed. Setting 0 is for
user-recorded and can only be used if a value has been stored at that location (see the previous section, "User-Recorded
EDID").
Rotary Switch
Position
Resolution
0 User-recorded EDID
1 800x600
2 1024x768 (default)
3 1280x720
4 1280x768
5 1280x800
6 1280x1024
7 1360x768
8 1366x768
9 1400x1050
A 1440x900
B 1600x1200
C 1680x1050
D 1920x1080
E 1920x1200
F Local monitor pass-through
4. Power on the display device.
5. Power on the source device.
Page view 2
1 2 3 4

Comments to this Manuals